Zhiwai issues SF6-free switchgear guide for Singapore and Johor data centres
Zhiwai has published a procurement guide for data-centre operators in Singapore and Johor that maps SF₆-free medium-voltage switchgear to common campus circuit duties. The guide also flags reporting, voltage, service-continuity and monitoring issues that buyers need to confirm before choosing equipment.
Why it matters: - Data-centre operators in Singapore and Johor need switchgear that matches utility voltages, fault duties and maintenance needs without locking in avoidable emissions. - SF₆ leakage counts as a direct greenhouse gas emission, so equipment choice affects both plant design and corporate carbon reporting. - The guide is aimed at buyers comparing SF₆-free options across primary distribution, transformer-feeder and ring-main duties.
What happened: - Zhiwai released a guide on specifying SF₆-free medium-voltage switchgear for data-centre campuses in Singapore and Johor. - The guide maps published Schneider Electric, ABB and Siemens products to common circuit duties. - The document draws on manufacturer, utility and regulatory materials and does not include independent product testing. - Zhiwai identified the guide as a document-based procurement resource for engineers, buyers and network operators.
The details: - Singapore and Malaysia are phasing in ISSB-based climate disclosures. - Operators and tenants should settle ownership, control and lease arrangements before assigning SF₆ emissions in Scope 1 inventories. - Singapore carbon-tax rules classify SF₆ from electrical equipment as non-reckonable, but that treatment does not remove the gas from corporate inventories. - Buyers should use the CO₂-equivalent factors required by the applicable reporting framework and check group procurement rules alongside local requirements. - SP Group lists 22 kV and 6.6 kV distribution connections. - TNB lists 33 kV and 11 kV, with other voltages in parts of Johor. - Large campuses can receive high-voltage supply and step it down to the campus MV level, so primary MV switchgear is not always at the utility intake. - A 33 kV circuit generally needs 36 kV-class equipment. - A 24 kV range does not cover 33 kV duty. - Buyers should check voltage, current, short-time withstand current, duration, and breaker making and breaking duties against utility requirements and fault studies. - Schneider Electric lists GM AirSeT primary GIS up to 36 kV using Pure Air. - Schneider Electric lists GM AirSeT Performance up to 24 kV. - Schneider Electric's MCSeT 24 with EvoPacT HVX offers primary AIS with a withdrawable vacuum circuit breaker. - ABB's UniGear portfolio includes ZS1 up to 24 kV and ZS2 up to 36 kV for withdrawable-breaker architectures. - Buyers should specify the vacuum-breaker version of ZS2 for SF₆-free deployments because the range also includes SF₆ breaker options. - Siemens' NXPLUS C 24 blue GIS uses Clean Air and fixed-mounted vacuum breakers for primary distribution up to 24 kV. - Buyers need to confirm the exact voltage version, ratings, local availability and utility acceptance because insulation type alone does not determine maintenance access. - RM AirSeT, SafeRing Air and SafePlus Air, and 8DJH 24 blue GIS serve transformer-feeder and ring-main applications up to 24 kV with air-based insulation. - SM AirSeT provides modular secondary AIS up to 24 kV. - Campus designs should specify functional units, circuit-breaker or switch-fuse protection, cable interfaces and extension arrangements. - These 24 kV ranges should not be substituted for a 36 kV-rated feeder. - Designers should define which compartments must stay accessible during planned work and which circuits must remain energized. - Under IEC 62271-200, buyers should select the loss of service continuity category, such as LSC2A or LSC2B, and the partition class, PM or PI, to match those access conditions. - Those classifications do not establish campus redundancy or fault recovery. - Internal arc requirements should identify accessibility type, protected sides, current, duration and pressure-relief arrangements. - Buyers should request type-test evidence for the offered assembly and verify installation conditions such as room clearances and exhaust paths. - Supply resilience also depends on feeder architecture, protection coordination and transfer arrangements. - Connected MCSeT with EvoPacT configurations can include thermal, environmental and selected breaker-health monitoring. - GM AirSeT options can include tank-pressure and breaker or mechanism data. - Buyers should require a sensor and data-point schedule for every offer, including included functions, options and service subscriptions. - Buyers should confirm any partial-discharge capability for the actual configuration. - Communication protocols, integration with building-management or supervisory control systems, cybersecurity responsibilities and local service response also need review. - Monitoring is also available on conventional switchgear and should be specified separately from the SF₆-free requirement. - Zhiwai's guide says the specification should identify what can stay energized during planned work and which ratings each campus circuit needs. - The guide also says buyers should get the proposed configuration, supporting test evidence and a clear schedule of monitoring and service commitments before comparing prices.
Between the lines: - The guide is as much a procurement checklist as a product comparison, because voltage class, access category, monitoring scope and service terms can change the real-world fit of a switchgear package. - The emphasis on utility acceptance and local requirements signals that a technically suitable product still may not be deployable without project-specific confirmation. - Zhiwai is positioning document-based research as a way to narrow options before buyers engage vendors or run detailed design studies.
What's next: - Data-centre buyers in Singapore and Johor will need to validate utility voltage, fault level and protection data before choosing a switchgear family. - Operators will also need to align procurement with emissions accounting rules, service continuity targets and monitoring requirements. - Zhiwai says it will continue publishing neutral, document-based product comparisons and procurement guides for Asian power users.
Disclaimer: This article was produced by AGP Wire with the assistance of artificial intelligence based on original source content and has been refined to improve clarity, structure, and readability. This content is provided on an “as is” basis. While care has been taken in its preparation, it may contain inaccuracies or omissions, and readers should consult the original source and independently verify key information where appropriate. This content is for informational purposes only and does not constitute legal, financial, investment, or other professional advice.
Sign up for:
Singapore News Digest
The daily local news briefing you can trust. Every day. Subscribe now.
Check Your Email!
We sent a one-time activation link to: .
Confirm it's you by clicking the email link.
If the email is not in your inbox, check spam or try again.
Welcome back!
is already signed up. Check your inbox for updates.